Related Experiment Video
Updated: Jul 11, 2025

Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
Published on: February 9, 2021
Radiological Density, Atomic Numbers, and Stone Fragmentation of Bego Stones Used for Research in Endourology:
Begoña Ballesta Martinez1,2,3, Daniel Savio Magee1, Arman Tsaturyan2
1Department of Urology, Royal Perth Hospital, Perth, Western Australia, Australia.
Abstract:
The aim of the study was to characterize artificial stones used for research in endourology in terms of radiological properties and hardness, based on stone fragmentation, and to compare them with real stones. We built artificial stones using BegoStone Plus™ powder (BEGO, Lincoln, RI), with powder (g)-water (mL) ratios ranging from 15:03 to 15:12. The CT Gemstone Spectral Imaging Software® (GE Medical Systems, LLC, Waukesha, WI) was used to evaluate the radiological density in HU and spectral properties. Stone fragmentation was assessed in an in vitro experimental setting. These properties of artificial stones were compared with real urinary calculi. Regarding radiological density in terms of HUs, 15:03 artificial calculi showed similar results when compared with real stones comprising calcium oxalate and calcium phosphate. The 15:03 and 15:04 artificial stones showed similar spectral property results to calcium pyrophosphate stones. The 15:11 artificial stones showed similar stone fragmentation results to real stones comprising uric acid, and 15:03 artificial calculi showed similar results to apatite and cystine stones. Artificial stones are useful for research in endourology. Stones with a powder (g)-water (mL) ratio of 15:03 proved to mimic real hard stones in terms of HUs, atomic number, and stone fragmentation in our study and could be used as artificial hard stones, and 15:11 stones showed similar stone fragmentation to uric acid stones. Our study might suggest that standard Bego stones are useful to investigate different areas in endourology, but not radiological properties because radiological homogeneity is not ensured unless more sophisticated mixing methods are used.
Related Concept Videos
Urinary Tract Calculi III: Medical Management
Urinary Tract Calculi VI: Surgical Management
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Urinary Tract Calculi II: Pathophysiology and Clinical Manifestations
Urinary Tract Calculi I: Introduction
Imaging Studies III: Computed Tomography