Related Experiment Video
Updated: Jul 11, 2025

Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models
Published on: September 27, 2024
A Method for Precise Reduction of Facial Bone Fractures Using Intraoperative Ultrasound With a Solid Gel Pad as a
Young Geun Kim1,2, Jeong-Ho Ryu3, Keun-Cheol Lee3
1Public health doctor, Yeongdong Hospital, Haman-gun, Gyeongsangnam-do, Korea.
Abstract:
This study introduces a method to overcome technical challenges in using intraoperative ultrasound for the closed reduction of nasal bone and zygomatic arch fractures. The curvature of the face makes it difficult to apply an ultrasound probe to the facial area. We used a solid gel pad as a coupling medium during surgery to improve the scanning of facial bone fractures. The results show that the fracture sites observed on preoperative computed tomography scans can be easily visualized using intraoperative ultrasound, and real-time manipulation confirms successful reduction. The solid gel pad is light, malleable, easy to use, and provides accurate images. Overall, the use of ultrasound with a solid gel pad enhances the accuracy of closed reduction in facial bone fracture surgeries, confirming fracture patterns and ensuring precise reduction.