Simple quantitative planimetric measurement of nigrosome-1 for clinical settings
Minh T Chau1, Marc Agzarian2, Robert A Wilcox3
1UniSA Allied Health & Human Performance and Alliance for Research in Exercise, Nutrition and Activity (ARENA), City East Campus, University of South Australia, GPO Box 2471, Adelaide, SA 5001, Australia; South Australia Medical Imaging, Flinders Medical Centre, 1 Flinders Drive, Bedford Park, SA 5042, Australia.
Introduction:
Loss of MRI hyperintense signal in nigrosome-1 (assessed with susceptibility-weighted imaging) is a biomarker for Parkinson's disease (PD). Current clinical practice involves subjectively rating the appearance of nigrosome-1 which is challenging. The study aimed to test and compare a simple method for quantifying nigrosome-1 with the current subjective rating method.
Methods:
Two experienced neuroradiologists measured area of hyperintense signal in nigrosome-1 (quantitative method) and rated nigrosome-1 appearance (as normal, attenuated, or absent; subjective method) in 42 patients encompassing the full spectrum of nigrosome-1 integrity (21 patients aged 55.5 ± 20.9 years with Essential tremor (ET) and a subset of 21 patients aged 69.6 ± 8.6 years with PD). Neuroradiologists were blinded to each other's measurements, clinical notes, and patient group.
Results:
Both methods yielded a significant difference between the groups (PD vs ET; p < 0.001). Pooled (across sides) area of nigrosome-1 hyperintense signal was significantly smaller in the PD group (median = 2.1 mm2, range = 0-15.8 mm2) than ET group (median = 8.3 mm2, range = 0-15.7 mm2; p < 0.001). Inter-rater reliability was high to very high for both methods (subjective: weighted kappa = 0.640, p < 0.001; quantitative: W = 0.733, p = 0.004). Our primary hypothesis that area of nigrosome-1 hyperintense signal exhibits higher inter-rater reliability than subjective rating of nigrosome-1 appearance was not supported.
Conclusion:
The simple quantitative method, used with subjectively rated nigrosome-1 appearance, may improve confidence in longitudinal clinical reporting, when nigrosome-1 is attenuated. However, further work on the incremental diagnostic value of planimetry and bias, repeatability and reproducibility are needed before it can be recommended in clinical practice.