Related Experiment Video
Updated: Jul 11, 2025

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
Published on: August 1, 2017
A white cell based broadband transient UV-vis absorption spectroscopy with pulsed laser photolysis reactors for
Frank A F Winiberg1, Wen Chao2, Rebecca L Caravan1
1Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109-8099, USA.
Abstract:
UV-vis spectroscopy is widely used for kinetic studies in physical chemistry, as species' absolute cross-sections are usually less sensitive to experimental conditions (i.e., temperature and pressure). Here, we present the design and characterization of a multipass UV-vis absorption spectroscopy white cell coupled to a pulsed-laser photolysis flow reactor. The glass reactor was designed to facilitate studies of gas phase chemical reactions over a range of conditions (239-293 K and 10-550 Torr). Purged windows mitigate contamination from chemical precursors and photolysis products. We report the measured impact of this purging on temperature uniformity and the absorption length and present some supporting flow calculations. The combined optical setup is unique and enables the photolysis laser to be coaligned with a well-defined absorption pathlength probe beam. This alignment leverages the use of one long-pass filter to increase the spectrum flatness and increase the light intensity vs other systems that use two dichroic mirrors. The probe beam is analyzed with a dual exit spectrograph, customized to split the light between an intensified CCD and photomultiplier tube, enabling simultaneous spectrum and single wavelength detection. This multipass system yields a pathlength of ∼450 cm and minimum observable concentrations of ∼3.7 × 1011 molecule cm-3 (assuming cross-sections ∼1.2 × 10-17 cm2). The temperature profile across the reaction region is ±2 K, defined by the worst-case temperature of 239 K, validated by measurements of the N2O4 equilibrium constant. Finally, the system is implemented to study the simplest Criegee intermediate, demonstrating the instrument performance and advantages of simultaneous spectrum and temporal profile measurements.
More Related Videos
09:53Molecular Beam Mass Spectrometry With Tunable Vacuum Ultraviolet VUV Synchrotron Radiation
Published on: October 30, 2012
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Related Concept Videos
UV–Vis Spectrometers
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
UV–Vis Spectroscopy: Molecular Electronic Transitions