Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Fast saliva analysis by GC-MS with Cold EI and Open Probe Fast GC-MS with Cold EI for the detection of cannabis usage
Oneg Elkabets1, Benny Neumark1, Aviv Amirav1,2
1School of Chemistry, Tel Aviv University, Tel Aviv, Israel.
Abstract:
Saliva is a body fluid that is much easier to collect and analyze than blood. Thus, saliva analysis for the detection of delta 9-tetrahydrocannabinol (delta 9-THC) can serve as a tool for law enforcement agents to detect cannabis consumption by drivers. Fast saliva analysis for the presence of delta 9-THC and/or cannabidiol (CBD) is described with both gas chromatography-mass spectrometry (GC-MS) with Cold electron ionization (EI) with good separation and in 10 min and/or with Open Probe Fast GC-MS with Cold EI in under 1 min full analysis cycle time. Saliva was taken directly from donors' tongues on a thin glass rod that was used "as is" for analysis. The saliva was thermally desorbed with a modified ChromatoProbe device inside the gas chromatograph (GC) injector and in an Open Probe (Agilent name QuickProbe) for its sub-1-min analysis. Cold EI is based on coupling of the GC and mass spectrometer (MS) with a supersonic molecular beam and on EI of vibrationally cold sample molecules during their flight through a contact-free ion source (thereby named Cold EI). A revised type of Open Probe Fast GC-MS on the bench is also described. Our saliva analysis was characterized by: Saliva can be collected in the field and transported to the lab for analyses "as is" without any sample preparation. Easy detection of cannabis consumption from cigarettes and/or other cannabis products. Distinction between the isomers delta 9-THC and CBD. Ultra-fast analysis in under 1 min using Open Probe Fast GC-MS with Cold EI.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II