Extraction and Characterization of Surfactants from Atmospheric Aerosols
Published on: April 21, 2017
An Eco-Friendly, Interference, and Solvent Free Surfactant-Assisted Dual-Wavelength β-CorrectionSpectrometric Method
Hassan Alwael1, Doaa S Al-Raimi2, Khairia M Al-Ahmary2
1Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia.
Abstract:
Spectral interference through the presence of uninformative variables, excess reagents, and complications in the refinement of the analyte signal is common in the quest to identify complex species in real samples. Therefore, an economical green, facile, and sensitive strategy has been developed for Cu2+ detection using the anionic surfactant sodium dodecylsulphate- (SDS-) assisted dual-wavelength β-correction spectrophotometric strategy combined with the chromogenic reagent zincon (ZI). The low limits of detection (LOD) and quantification (LOQ) of Cu2+ using ordinary (single wavelength) spectrophotometry were 0.19 (3.02) and 0.63 (10.0) μgmL-1, and these values were improved to 0.08 (1.27) and 0.26 μgmL-1 (4.12 μM)) using β-correction (dual wavelength) spectrophotometry, respectively. The LOD and LOQ were improved from 0.08 (1.27) and 0.26 (4.12) μgmL-1 to 0.02 (0.32) and 0.08 μgmL-1 (1.27 μM) using SDS-assisted dual-β-correction spectrometry, respectively. Ringbom, s, and the corrected absorbance (A) versus Cu2+ concentration plots were linear over the concentration range 1.10-2.4 (17.4-38.1) and 0.50-2.40 μgmL-1 (7.94-38.1 μM), respectively. Sandell's sensitivity index of 3.0 × 10-3 μg/cm2 was achieved. The selectivity was further confirmed via monitoring the impact of common diverse ions and surfactants on the corrected absorbance. Total determination and Cu2+ speciation in water were favorably implemented and validated by ICP-OES at 95% (P=0.05). Satisfactory Cu2+ recoveries in tap (92.2-98.0%) and mineral (105-111.0%) water samples were achieved. The sensing system is simple, reliable, sensitive, and selective for Cu2+ detection.
Related Concept Videos
Precipitation and Co-precipitation
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Extraction: Advanced Methods
Electrodeposition
Electrodeposition can...