Related Experiment Video
Updated: Jul 11, 2025

High-Speed Human Temporal Bone Sectioning for the Assessment of COVID-19-Associated Middle Ear Pathology
Published on: May 18, 2022
Partial transection of the external ear caused by a mask worn for COVID-19 protection
Fuko Omine1, Junya Oshima2, Yasushi Haga3
1Mito Medical Center: Kokuritsu Byoin Kiko Mito Iryo Center, Ibaraki, Japan.
Introduction:
During the COVID-19 pandemic surgical mask-wearing was widely adopted as a means of preventing infections, but there have been several reports of mask-induced skin problems. In this report, we describe a case in which surgery was required for a mask-induced ear injury.
Case Report:
An otherwise healthy 63-year-old male presented to the plastic surgery department with an auricle injury. He had been using a mask that was too small for his face for more than 1 month; the tight ear loops caused the upper part of his left auricle to begin to dissect, resulting in a large tear. More than a third of the left upper auricle was torn, and the wound surface was epithelialized. The patient had no history of skin disease or psychiatric disorder but was engaged in a job that required wearing a helmet constantly. Surgery was performed to refresh the epithelialized wound surface and suture it, and the patient healed without complication.
Conclusion:
While mask-wearing mandates and recommendations have considerably eased since the height of the pandemic, the current authors' experience has brought to light problems related to mask usage. Thus, efforts should be made to investigate the causes of these problems and provide appropriate advice.
More Related Videos
12:21The Mouse Round-window Approach for Ototoxic Agent Delivery: A Rapid and Reliable Technique for Inducing Cochlear Cell Degeneration
Published on: November 26, 2015
07:06Endaural Endoscopic Atticoantrotomy Retrograde Mastoidectomy using a Constant Suction Bone-drilling Technique
Published on: May 23, 2021
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
PPE Use in Healthcare Settings II: Doffing
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...