Related Experiment Video
Updated: Jul 11, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
A comparison of tracheal intubation using intubrite laryngoscope and conventional MAC laryngoscope: An open,
Pawel Ratajczyk1, Michal Fedorczak, Przemyslaw Kluj
1Department of Anesthesiology and Intensive Therapy, Medical University of Lodz, Poland.
Background:
New devices are more available in the pre-hospital environment operational theaters and emergency departments. One is an intubrite laryngoscope (INT) with Dual LED lighting that combines ultraviolet and white LED. The study aimed to compare the efficacy of endotracheal intubation using INT and conventional laryngoscope performed by inexperienced paramedics (paramedics students) and paramedics with experience in advanced airways management in full and limited accessibility settings.
Methods:
It was an open, prospective, crossover manikin study. Sixty paramedics and paramedic students were recruited. Participants were divided into 2 equal groups depending on their experience (n = 30). Experienced participants were further randomly divided into 2 groups (n = 15). Inexperienced participants were also randomly divided into 2 groups (n = 15). The criterion of inexperience was 5 or fewer intubation by any laryngoscope. Inexperience participants were asked to perform tracheal intubation in standard pre-hospital settings (without limited access to manikin) (scenario A) and difficult pre-hospital settings (limited access to manikin - narrow space between benches) (scenario B). Experience participants were asked to intubate manikin in difficult pre-hospital settings.
Results:
In the normal pre-hospital environment, the success rate after the first attempt was 56,7% for conventional laryngoscope and 66,7% for intubrite. However, the overall effectiveness of tracheal intubation using both laryngoscopes in 3 attempts was 90% for both devices. The successful rate of first attempt intubation in a difficult environment by inexperienced was 73,3% for INT and 50% for conventional laryngoscope. Overall effectiveness was 83,3% and 86,7% respectively. The successful rate of first attempt intubation in the experienced group was 86,7% with INT compared to 60% with a conventional laryngoscope in difficult settings. Overall effectiveness was 96,7% for both devices.
Conclusion:
Intubrite provided better working conditions and make up for deficiencies in successful tracheal intubation by inexperienced participants in a normal and difficult environment. Tracheal intubation with intubrite was more effective in the experienced group. Tracheal intubation effectiveness with intubrite was also higher in the experienced group.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: