Ultrasound guidance practices used for the placement of vascular accesses in intensive care units: an observational
Nathalie van der Mee-Marquet1, Anne-Sophie Valentin2, Isabelle Duflot2
1National Network for Surveillance and Prevention of Infections Associated with Invasive Devices (SPIADI Network), Centre d'Appui Pour la Prévention des Infections Associées Aux Soins (Cpias) Centre Val de Loire, Hôpital Bretonneau, Centre Hospitalier Régional Universitaire, 37044, Tours, France. n.vandermee@chu-tours.fr.
Background:
Central catheters expose ICU patients at risk of catheter-related bloodstream infections. A mechanism by which these infections occur is the contamination of the catheter during its insertion if aseptic techniques are not strictly applied. Recent studies suggest that the use of ultrasound guidance (USG) may increase the risk of catheter contamination during insertion. We assessed current practices regarding the use of USG during catheter insertion, with a focus on identifying breaches of the surgical asepsis required for this invasive procedure.
Methods:
In 26 intensive care units, we evaluated the use of USG during catheter insertion, using a questionnaire addressed to intensivists and direct observation of their practices.
Results:
We analyzed 111 questionnaires and 36 observations of intensivists placing catheters. The questionnaires revealed that 88% of intensivists used USG for catheter insertion. Among those using USG, 56% had received specific training, 17% benefited from specific recommendations, 76% marked the insertion site before skin antisepsis, and during catheter insertion, 96% used sterile gel and 100% used a sterile sheath and sterile gloves. We identified potential deviations from strict aseptic technique, including contact between the sheath and the needle (19.4%), handling of the US system during catheter insertion (2.8%), and use of sterile devices, where they were not yet necessary (during the marking site or skin antisepsis), resulting in their contamination at the time of catheter insertion.
Conclusions:
Interventions aimed at ensuring compliance with measures to prevent CRBs should be organized to prevent an increase in infections associated with US-guided catheter insertion.
More Related Videos
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies VII: Vascular Imaging