Assessment of Radiation Exposure with Mandatory Two Fluoroscopic Views for Epidural Procedures
Laxmaiah Manchikanti1, Rachana Pasupuleti2, Vidyasagar Pampati3
1Pain Management Centers of America, Paducah, KY and Evansville, IN; LSU Health Science Center, New Orleans, LA.
Background:
Various regulations and practice patterns develop on the basis of Local Coverage Determination (LCD), which are variably perceived as guidelines and/or mandated polices/ regulations. LCDs developed in 2021 and effective since December 2021 mandated a minimum of 2 views for final needle placement with contrast injection which includes both anteroposterior (AP) and lateral or oblique view. Radiation safety has been a major concern for pain physicians and multiple tools have been developed to reduce radiation dose, along with improvement in technologies to limit radiation exposure while performing fluoroscopically guided interventional procedures, with implementation of principles of As Low As Reasonably Achievable (ALARA). The mandated 2 views of epidural injections have caused concern among some physicians, because of the potential of increased exposure to ionizing radiation, despite application of various principles to minimize radiation exposure. Others, including policymakers are of the opinion that it reduces potential abuse and improves safety.
Objective:
To assess variations in the performance of epidural procedures prior to the implementation of the new LCD compared with after the implementation of the new LCD by comparing time and dosage for all types of epidural procedures.
Study Design:
A retrospective, case controlled, comparative evaluation of radiation exposure during epidural procedures in interventional pain management.
Setting:
An interventional pain management practice and a specialty referral center in a private practice setting in the United States.
Methods:
The study was performed using the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) criteria. The main outcome measure was radiation exposure time measured in seconds and dose measured in mGy-kG2 (milligray to kilogray squared per procedure).
Results:
Changes in exposure and dose varied by procedural type and location. Exposure time in seconds increased overall by 21%, whereas radiation dose mGy-kG increased 133%. Fluoroscopy time increased most for lumbar interlaminar epidural injections of 43%, followed by 29% for cervical interlaminar epidural injections, 20% for caudal epidural injections, and 14% for lumbar transforaminal epidural injections. In contrast, highest increases were observed in the radiation dose mGy of 191% for caudal epidural injections, followed by 173% for lumbar interlaminar epidural injections, 113% for lumbar transforaminal epidural injections, and the lowest being cervical interlaminar epidural injections of 94%. This study also shows lesser increases for cervical interlaminar epidural injections because an oblique view is utilized rather than a lateral view resulting in a radiation dosage increase of 94% compared to overall increase of 133%, whereas the duration of time of 29% was higher than the overall combined duration of all procedures which only increased by 21%.
Limitations:
A retrospective evaluation utilizing the experience of a single physician.
Conclusion:
The results of this study showed significant increases in radiation exposure time and dosage; however, increase of dosage was overall 21% median Interquartile Range (IQR) compared to 133% of radiation dose median IQR. In addition, the results also showed variations for procedure, overall showing highest increases for lumbar interlaminar epidural injections for time (43%) and caudal epidural injections for dosage (191%).
More Related Videos
03:14Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Imaging Studies VII: Vascular Imaging
Radiological Investigation I: X-ray and CT
X-ray Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...