Pressure-controlled ventilation-volume guaranteed mode improves bronchial mucus transport velocity in patients during
Chao Deng1,2, Tao Xu3, Xue-Kai Wang1
1Department of Anesthesiology, First Affiliated Hospital, Shihezi University, Shihezi, China.
Background:
Mechanical ventilation during general anesthesia may impair airway mucosal function. This study aimed to investigate the effect of pressure-controlled ventilation-volume guaranteed (PCV-VG) on bronchial mucus transport velocity (BTV) in patients during laparoscopic surgery for gynecological oncology compared with volume controlled ventilation (VCV).
Methods:
66 patients undergoing elective a laparoscopic surgery for gynecological oncology. The patients were randomized into two group receiving either PCV-VG or VCV. a drop of methylene blue was placed on the surface of the airway mucosa under the bronchoscopeand, then the distance the dye movement was measured after 2, 4, and 6 min. Outcomes were assessed at T0 (5 min after endotracheal intubation and before initiation of pneumoperitoneum), T1 and T2 (1 and 2 h after stabilization of pneumoperitoneum respectively). BTV at T0, T1 and T2 was the primary outcome. Secondary outcomes included heart rate (HR), mean arterial pressure (MAP), body temperature, end-tidal CO2 pressure (PETCO2), tidal volume(VT), peak inspiratory pressure (PIP), mean inspiratory pressure (Pmean), respiratory rate (RR), and dynamic compliance (CDyn) at T0, T1, and T2.
Results:
64 patients were included in the analysis. The median [interquartile range] BTV was significantly lower in VCV group at T1 and T2 that at T0 (P < 0.05). Furthermore, BTV was slightly reduced in PCV-VG compared with VCV. BTV in PCV-VG was significantly decreased at T2 compared with BTV at T0 (P < 0.05) and slightly decreased at T1 compared with T0(P > 0.05). Compared with the PCV-VG group, BTV in VCV group significantly decreased at T2 (P < 0.05). No participants experienced respiratory complications.
Conclusions:
PCV-VG is more suitable for patients undergoing laparoscopic surgery for gynecological oncology than VCV since it can protect mucociliary clearance function.
Trial Registration:
This trial is registered on https://www.chictr.org.cn/ in Chinese Clinical Trial Registry (ChiCTR.2200064564: Date of registration 11/10/2022).
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...