A Technique for Centrifugal Pump Fault Detection and Identification Based on a Novel Fault-Specific Mann-Whitney Test
Zahoor Ahmad1, Jae-Young Kim2, Jong-Myon Kim1,2
1Department of Electrical, Electronic and Computer Engineering, University of Ulsan, Ulsan 44610, Republic of Korea.
Abstract:
This work presents a technique for fault detection and identification in centrifugal pumps (CPs) using a novel fault-specific Mann-Whitney test (FSU Test) and K-nearest neighbor (KNN) classification algorithm. Traditional fault indicators, such as the mean, peak, root mean square, and impulse factor, lack sensitivity in detecting incipient faults. Furthermore, for defect identification, supervised models rely on pre-existing knowledge about pump defects for training purposes. To address these concerns, a new centrifugal pump fault indicator (CPFI) that does not rely on previous knowledge is developed based on a novel fault-specific Mann-Whitney test. The new fault indicator is obtained by decomposing the vibration signature (VS) of the centrifugal pump hierarchically into its respective time-frequency representation using the wavelet packet transform (WPT) in the first step. The node containing the fault-specific frequency band is selected, and the Mann-Whitney test statistic is calculated from it. The combination of hierarchical decomposition of the vibration signal for fault-specific frequency band selection and the Mann-Whitney test form the new fault-specific Mann-Whitney test. The test output statistic yields the centrifugal pump fault indicator, which shows sensitivity toward the health condition of the centrifugal pump. This indicator changes according to the working conditions of the centrifugal pump. To further enhance fault detection, a new effect ratio (ER) is introduced. The KNN algorithm is employed to classify the fault type, resulting in promising improvements in fault classification accuracy, particularly under variable operating conditions.
More Related Videos
Related Concept Videos
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Power System Three-Phase Short Circuits
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Angle of Twist: Problem Solving