Related Experiment Video
Updated: Jul 10, 2025

Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
Positional relationships between a tracheal diverticulum and the tracheal tube under general anesthesia: a
Kunihiro Mitsuzawa1,2, Tsukasa Kumagai3, Haruo Uchida3
1Department of Anesthesiology and Resuscitology, Shinshu University School of Medicine, 3-1-1, Asahi, Matsumoto City, Nagano, 390-8621, Japan. mitsukuni@shinshu-u.ac.jp.
Background:
Incomplete sealing of tracheal diverticula by a tracheal tube cuff during positive-pressure ventilation causes barotrauma but the concrete possibility of incomplete sealing has not been indicated. We aimed to assess the possibility of incomplete sealing in a simulated situation of tracheal intubation for patients with tracheal diverticula with tube fixation where the tracheal tube's vocal cord guide overlaps with the patient's vocal cord.
Methods:
We retrospectively assessed the characteristics of tracheal diverticula based on thoracic computed tomography data in our institution from January 2018 to July 2020. Then, we assessed the structural parameters of three single-lumen tracheal tubes (Parker Flex-Tip [Parker Medical, Bridgewater, CT, USA], Portex Soft Seal [ICU Medical, San Clemente, CA, USA], and Shiley TaperGuard [Medtronic, Dublin, Ireland]; 6.0-8.0 mm inner diameter size) and simulated the positional relationships between tracheal diverticula and the tracheal tube during tracheal intubation where the vocal cord guide overlaps with the patient's vocal cord. We assessed each tube product's possibility of incompletely sealing tracheal diverticula and the possibility of unintended bronchial intubation.
Results:
In 5,854 patients, the prevalence of tracheal diverticula was 5.7%. The mean (SD) length from the vocal cord to the distal end of the tracheal diverticula was 52.2 (12.8) mm. Tracheal tubes with length from the distal end of the tracheal cuff to the vocal cord guide of ≥ 70 mm had a low risk of incompletely sealing tracheal diverticula (< 5%) and length from the distal end of the tube to the vocal cord guide of ≤ 95 mm had a low risk of unintended bronchial intubation (< 5%). No products in this study satisfied both outcomes.
Conclusions:
Tube fixation, where the vocal cord guide overlaps with the patient's vocal cord, is associated with risk of incompletely sealing of tracheal diverticula depending on the tube's manufacturer and tube's inner diameter size, although it was not a high risk. The use of small inner diameter sized tube relative to patient's body size is high risk of incomplete sealing of tracheal diverticula.
Trial Registration:
This trial was prospectively registered at University Hospital Medical Information Network (UMIN).
Clinical Trial Number And Registry Url:
UMIN000043317 (URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000048055 ).
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...

