Related Experiment Video
Updated: Jul 9, 2025

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Modeling of analytical, preparative and industrial scale counter-current chromatography separations
Artak E Kostanyan1, Andrey A Voshkin1
1Kurnakov Institute of General & Inorganic Chemistry, Russian Academy of Sciences, Leninsky a Prospekt 31, Moscow 119991, Russia.
Abstract:
Analytical, preparative and industrial scale counter-current chromatography (CCC) processes differ in the volumes of the loaded solution of components to be separated and in the design of the equipment. Preliminary mathematical modeling is necessary for selection of the optimal design and operation mode of these CCC separations. This study aims to compare simulations of CCC separations at different scales, using an exact description based on the model of equilibrium cells and a much simpler approximate solution based on the Gaussian distribution. Equations for modeling CCC separations of different scales and examples of simulation these separations are presented. It is shown that the discrepancy between the two simulations increases with an increase in the volume of the loaded solution of the components and a decrease in the number of equilibrium cells of a CCC device. In analytical and preparative separations, which are based on complex centrifugal devices, and relatively small sample volumes are injected, approximate equations can be used to simulate various options of CCC separation. In industrial-scale CCC separations, large volumes of the solution of components may be loaded, and as we have proposed previously, these separations can be based on a cascade of mixer-settler extractors. In this case, a more accurate mathematical description based on the cell model equations should be used for modeling.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Instrumentation
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...