Neurointerventions on two generations of angiography systems: Recent systems reduce radiation exposure by half
Xinhua Li1, Kai Yang1, Theodore A Marschall1
1Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA.
Purpose:
Fluoroscopically-guided neurointervention may be associated with prolonged procedure time and substantial radiation exposure to the patient and staff. This study sought to examine technological features affecting the potential radiation exposure reduction of new angiography systems, compared to older systems, for neurointerventional procedures.
Methods:
Consecutive neurointerventional patients (2020-2022) were retrospectively analyzed. The air kerma at the reference point (Ka,r) and kerma-area product (KAP) were compared between Artis icono and Artis zee (Siemens) using statistical analyses (two-tailed t tests), where P < 0.05 is considered significant. X-ray tube potential and copper filtration were examined. Tests with an anthropomorphic phantom (Sun Nuclear) on Artis icono were conducted and entrance skin exposure and x-ray spectral half value layer were measured. Effective spectral filtration was characterized by x-ray spectral modeling.
Results:
The number of procedures was 1158 [median (range) age, 59 (7-95) years] on Artis zee and 1087 [60 (1-95) years] on Artis icono, without significant difference in age (p = 0.059) between cohorts. Ka,r was 925.4 (890.6-960.1) mGy [mean (95 % CI)] and KAP was 119.8 (115-124.5) Gy∙cm2 on Artis zee. The measures were 48-50 % lower on Artis icono, 440.5 (411.7-469.4) mGy (Ka,r) and 59.5 (55.4-63.6) Gy∙cm2 (KAP); while the difference in fluoroscopic time between the two generations of angiography systems was insignificant (p = 0.55).
Conclusions:
The newer angiography system, with updated hardware and software, was found to result in half the radiation exposure compared to older technology of the same manufacturer, even though fluoroscopic time was similar.
More Related Videos
08:30X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT