Background:
With the COVID-19 pandemic, body temperature measurement has begun to be widely used in the diagnosis of the coronavirus disease. When measuring body temperature, it is important to obtain the core temperature measurement. This study compared the results of body temperature obtained with the tympanic membrane thermometer-which is one of the methods that best reflect the body temperature-with or without positioning the auricle.
Aims:
The aim of this study was to investigate the effect of auricle position on body temperature measurements made with tympanic membrane thermometer in adult patients.
Materials And Methods:
A quasi-experimental design that employed a pre-test and a post-test was used in this study. A total of 143 patients who fit the inclusion criteria of the study were included in the sample. For analysis of the data, frequencies, percentages, means and standard deviations were calculated, and the significance of the difference between paired values was tested in order to investigate the effects of auricle position on measurement values. Statistical Package for the Social Sciences (SPSS) 22.0 was used in analyzing the data obtained in this study.
Results:
The difference between the values of measurement taken in these two separate positions was found to be 0.31 0C, and the Bland-Altman plot showed that the differences were distributed systematically around the value 0.31.
Conclusions:
It was found in the comparison of two positions that there was a significant difference between the tympanic thermometer measurements made by positioning the auricle and those without positioning.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...