Implementation of Above-Cuff Vocalization After Tracheostomy Is Feasible and Associated With Earlier Speech
Srdjan Gajic1, Lauren Jacobs2, Catherine Gellentien2
1Division of Pulmonary, Allergy and Critical Care, Department of Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia.
Purpose:
The purpose of this study was to assess the feasibility of hospital-wide implementation of an above-cuff vocalization (ACV) protocol using ACV-capable tracheostomy tubes and its impact on patient speech in four intensive care unit (ICU) patient populations.
Method:
This research was an observational pre-post study that was conducted over a 26-month period and included 323 critically ill adult ICU patients who underwent tracheostomy in a 365-bed academic tertiary care hospital. ACV was assessed using a protocol developed by a multidisciplinary team. Presence of speech was defined as at least one comprehensible word spoken during a speech-language pathologist evaluation.
Results:
Median time-to-speech was 13 days (interquartile range [IQR]: 8-20 days) before the intervention, compared to 9 days (IQR: 6-16 days) after the intervention (p = .0017). In the pre-intervention group, 101 out of 167 (60.5%) patients achieved speech within 60 days, compared to 83 out of 133 (62.4%) patients in the post-intervention group (p = .12). Of the 83 patients who achieved speech in the post-intervention group, 24 (28.9%) did so via ACV, with the remainder using a speaking valve or digital occlusion. Of those 24 patients, seven did not progress to using a speaking valve within the follow-up period. The median number of speech days gained by using ACV was 8 (IQR: 5-18 days). ACV was successful in facilitating speech in 24 out of 29 (82.8%) patients trialed, with no major complications.
Conclusions:
Routine implementation of ACV after tracheostomy is feasible, safe, and associated with earlier speech in a diverse population of critically ill patients. ACV is an important method to facilitate communication in patients requiring mechanical ventilation with tracheostomy cuff inflation.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....