Retrospective cohort study of wrong-patient imaging order errors: how many reach the patient?
Jerard Z Kneifati-Hayek1, Elias Geist2, Jo R Applebaum1
1Department of Medicine, Columbia University Irving Medical Center, New York, New York, USA.
Abstract:
Studying near-miss errors is essential to preventing errors from reaching patients. When an error is committed, it may be intercepted (near-miss) or it will reach the patient; estimates of the proportion that reach the patient vary widely. To better understand this relationship, we conducted a retrospective cohort study using two objective measures to identify wrong-patient imaging order errors involving radiation, estimating the proportion of errors that are intercepted and those that reach the patient. This study was conducted at a large integrated healthcare system using data from 1 January to 31 December 2019. The study used two outcome measures of wrong-patient orders: (1) wrong-patient orders that led to misadministration of radiation reported to the New York Patient Occurrence Reporting and Tracking System (NYPORTS) (misadministration events); and (2) wrong-patient orders identified by the Wrong-Patient Retract-and-Reorder (RAR) measure, a measure identifying orders placed for a patient, retracted and rapidly reordered by the same clinician on a different patient (near-miss events). All imaging orders that involved radiation were extracted retrospectively from the healthcare system data warehouse. Among 293 039 total eligible orders, 151 were wrong-patient orders (3 misadministration events, 148 near-miss events), for an overall rate of 51.5 per 100 000 imaging orders involving radiation placed on the wrong patient. Of all wrong-patient imaging order errors, 2% reached the patient, translating to 50 near-miss events for every 1 error that reached the patient. This proportion provides a more accurate and reliable estimate and reinforces the utility of systematic measure of near-miss errors as an outcome for preventative interventions.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Types of Reports III: Telephone and Verbal Reports
Here's an overview of each type:
Telephone Orders