Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Fingertip Strain Plethysmography: Representation of Pulse Information based on Vascular Vibration
Abstract:
This study presents fingertip strain plethysmography (SPG) as a visual trace of cardiac cycles in peripheral vessels. The setup includes a small, sensitive MEMS strain sensor attached to the fingertip to capture the pulsatile vibrations corresponding to cardiac cycles. SPG is evaluated on 10 healthy subjects for the estimation of heart rate (HR) and heart rate variability (HRV), as well as heartbeat-derived respiratory rate (RR) which is an HRV parameter. The estimated parameters are compared with a simultaneously-recorded electrocardiogram (ECG) for HR and HRV, and an inertial sensor placed on the chest wall for RR. Bland-Altman analyses suggest small estimation biases of 0.03 beats-per-minute (BPM) and 0.38 ms for HR and HRV respectively, demonstrating excellent agreement between fingertip SPG and ECG. The average estimation accuracies of 99.88% (± 0.04), 96.43% (± 1.44), and 92.64% (± 2.30) for HR, HRV, and RR respectively, prove the reliability of SPG for hemodynamic monitoring.Clinical Relevance- Conventional plethysmography sensors are either cumbersome or susceptible to skin color. This effort is a fundamental step towards the augmentation of conventional methods, thus ensuring stable, clinical-grade hemodynamic monitoring.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pulse Assessment Sites
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...