Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
New Perspectives on Non-invasive Blood Pressure Measurement
Abstract:
Noninvasive blood pressure (NIBP) devices are calibrated against validated auscultation sphygmomanometers using Korotkoff sounds. This study aimed to investigate the timing of Korotkoff sounds in relation to pulse appearance in the brachial artery and values of intra-arterial blood pressure. Experiments were carried out on 15 participants, (14 males, 64.3 ± 10.4 years; one female, 86 yo), undergoing coronary angiography. A conventional occluding cuff, with a microphone for Korotkoff sounds, was placed on the upper arm (on the brachial artery). Intra-arterial blood pressure (IABP) was measured below the cuff with a fluid-filled catheter inserted via the radial artery and an external transducer. Finger photoplethysmography was used to measure brachial pulse wave velocity (PWV). Korotkoff sounds were processed electronically and custom algorithms identified the cuff pressure (CP) at which the first and last Korotkoff sounds were heard. PWV and max slope of the IABP pressure pulse were recorded to estimate arterial stiffness. The brachial artery closed at a CP of 132.0 ± 17.1 mmHg. Systolic and diastolic blood pressure (SBP and DBP) were 147.6 ± 14.3 and 72.7 ± 10.1 mmHg; mean pressure (MP, 100.1 ± 10.4 mmHg) was similar to MP derived from the peak of the oscillogram (98.5 ± 13.6 mmHg). Difference between IABP and CP recorded at first and last occurrence of Korotkoff sounds were, SBP: 19.0 ± 8.3 (range 2-29) mmHg, DBP: 4.0 ± 4.3 (range 2-12) mmHg. SBP derived from the onset of Korotkoff sounds can underestimate IABP by up to 19 mmHg. Since Korotkoff sounds are the recommended method mandated by the universal standard for the validation of blood pressure measuring devices, these errors are propagated through to all NIBP measurement devices irrespective of whether they use auscultatory or oscillometric methods.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure