Comparison of visual outcomes of bilateral dual-technology diffractive intraocular lens vs blended enhanced monofocal
Wilson Takashi Hida1, Bernardo Kaplan Moscovici, Cesar Martins Cortez
1From the Department of Ophthalmology, Hospital Oftalmológico de Brasília (HOB), Brasília, Brazil (Hida, Cortez, Tzelikis); Department of Ophthalmology, University of Sao Paulo (HC-FMUSP), Sao Paulo, Brazil (Hida, Carricondo); Department of Ophthalmology and Visual Sciences, Federal University of Sao Paulo (UNIFESP), Sao Paulo, Brazil (Moscovici, Nose); Department of Ophthalmology, Hospital Visão Laser, Santos, Brazil (Moscovici, Colombo-Barboza, Tzelikis); Department of Ophthalmology, Renato Ambrosio Research Center (CEORA), Brasília, Brazil (Cortez, Tzelikis, Motta, De Medeiros).
Purpose:
To compare clinical outcomes after implantation of TECNIS Synergy (ZFR00V) intraocular lenses (IOLs) in both eyes and implantation of the TECNIS Synergy and TECNIS Eyhance (ICB00) combination in patients undergoing cataract surgery.
Setting:
Department of Cataract, Hospital Oftalmológico de Brasilia (HOB), Brasília, Brazil.
Design:
Prospective, interventional, randomized, parallel-group study.
Methods:
Patients were categorized into 2 groups: Group 1: ZFR00V IOL was implanted in both eyes. Group 2: An ICB00 IOL was implanted in the dominant eye, and a ZFR00V IOL was implanted in the nondominant eye.
Results:
Visual acuity was similar between the 2 groups (95% CI <0.1 logMAR). A superior visual acuity of ≥ 20/25 (at -2.00 to -2.50 diopters [D]) was achieved in Group 1 (bilateral ZFR00V) than in Group 2 (combination of ZFR00V/ICB00). The binocular defocus curve demonstrated better visual acuity at 40 cm (-2.00 D) and 50 cm (-2.50 D) in Group 1 than in Group 2 ( P < .05). Similar contrast sensitivity values were observed between the 2 groups. Patients in Group 1 reported higher satisfaction (completely satisfied) than those in Group 2 ( P < .05). However, halos and glare were more pronounced in Group 1 than in Group 2 ( P < .05).
Conclusions:
Both presbyopia-correcting IOL combinations showed similar binocular visual acuity results. Group 1 demonstrated enhanced visual acuity in the defocus curve at 40 cm (-2.00 D) and 50 cm (-2.50 D). Comparable contrast sensitivity outcomes were observed in both groups. Patients were more completely satisfied in Group 1 than in Group 2, despite the higher frequency of postoperative nighttime halos and glare.
More Related Videos
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
07:45Assessing Binocular Central Visual Field and Binocular Eye Movements in a Dichoptic Viewing Condition
Published on: July 21, 2020
Related Concept Videos
Focusing of Light in the Eye
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...