Related Experiment Video
Updated: Jul 8, 2025

Importance of Jumping Ability in Handball Throwing Speed and Accuracy
Published on: April 4, 2025
Concurrent Validity and Reliability of In-Field Vertical Jump Performance Measures on Sand Surfaces
Svenja Wirtz1, Ross Julian1,2, Rieke Schmale1
1Department of Neuromotor Behavior and Exercise, Institute of Sport and Exercise Sciences, University of Münster, Münster, Germany; and.
Abstract:
Wirtz, S, Julian, R, Schmale, R, and Eils, E. Concurrent validity and reliability of in-field vertical jump performance measures on sand surfaces. J Strength Cond Res 38(4): 687-693, 2024-Beach sports, such as handball, volleyball, and soccer, involve dynamic actions, primarily jumps. Nonetheless, there is a need for more established measurement devices that are both valid and feasible in accurately evaluating jumping performance on sand surfaces. This study aims to assess the reliability and concurrent validity of MyJump2 and an inertial measurement unit (VERT) for quantifying countermovement jump performance on the sand. Twenty-one subjects performed 5 countermovement jumps on the sand. Jumping height was measured simultaneously by a force plate, VERT, and MyJump2. The VERT and MyJump2 reliability measures were evaluated using the intraclass correlation coefficients (ICC) for both absolute agreement (ICC 2,1 ) and consistency (ICC 3.1 ). The day-to-day reliability of both devices and the interrater and intrarater reliability of the MyJump2 were assessed. The concurrent validity of the VERT and MyJump2 was assessed using ICCs 2.1, 3.1 and Bland-Altman plots. A near-perfect agreement was seen for intrarater (ICC = 0.98) and interrater (ICC = 0.98) reliability of the MyJump2. Moreover, a near-perfect agreement was also observed when comparing the MyJump2 with the force plate (ICC = 0.92), with a mean bias of -2.31 cm. The VERT device only demonstrated a moderate agreement (ICC = 0.55) with a mean bias of 6.31 cm compared with the force plate, despite showing good day-to-day reliability (ICC = 0.79). The study's results indicate that MyJump2 is valid and reliable for assessing jump heights on sand surfaces, whereas VERT cannot be recommended.
More Related Videos
08:21Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
Published on: June 8, 2017
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Impact: Problem Solving
By designating the launch point as the origin and utilizing kinematic equations, the vertical component of the projectile's velocity at the point of impact is...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Toughness and Hardness of Aggregate
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Reliability and Validity