Insulin infusion sets associated with adverse events: strategies for improved diabetes education
Ana Lucia Domingues Neves1, Luiz Eduardo Galvão Martins2, Mônica Andrade Lima Gabbay3,4
1Postgraduate Program in Translational Medicine, Department of Medicine, Paulista School of Medicine, Federal University of São Paulo, São Paulo, Brazil.
Introduction:
Insulin Infusion Sets (IIS) play a crucial role in ensuring the safe delivery of insulin through a Continuous Subcutaneous Insulin Infusion (CSII) for individuals with Type 1 Diabetes (T1D). Recent advancements in therapy have highlighted the need to address issues such as unexplained hyperglycemia and IIS occlusion.
Objective:
To investigate the adverse events (AEs) associated with IIS that impact the treatment of T1D, with a specific focus on promoting effective educational practices.
Methods:
One hundred and eighteen patients under treatment at the Diabetes Center Insulin Pump Ambulatory, Federal University of São Paulo responded to a semi-structured questionnaire. Over 6 months, a nurse researcher interviewed them via video calls.
Results:
Catheter-related adverse events (AEs) included catheter knots, folding, and accidental traction. AEs associated with cannula use were mainly related to cannula fixation adhesive, insulin leakage, bleeding episodes, and skin problems. The cannula patch tends to detach easily in hot conditions or when used for more than 3 days, leading to local itching. Adhesive glue can cause redness and pain. Insulin leakage typically occurs after the catheter disconnects from the cannula, accidental cannula traction, or beneath the cannula patch. Bleeding has been reported inside the cannula or at the insertion site, resulting in local pain and, in some cases, obstruction of insulin flow. When accidental cannula traction occurs, it is recommended to replace the entire IIS system. In situations involving bleeding, leakage, insulin odor, or unsuccessful attempts to correct hyperglycemic episodes with a "bolus" of insulin, it is advisable to change the IIS system and evaluate appropriate techniques for handling and infusing the device. Moreover, regular inspections of the device and reservoir/cartridge are essential.
Conclusion:
Serious AEs can occur even in cases where the occlusion alarm is not activated, leading to interruptions in insulin flow. Conversely, in less severe situations, alarm activation can occur even in the absence of insulin flow interruption. Accidental catheter traction and catheter bending are commonly encountered in everyday situations, while issues related to the cannula directly affect blood glucose levels. AEs related to the IIS cannula often involve insulin leakage into the skin, bleeding, and skin events attributed to adhesive issues with the cannula.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Hypoglycemia and Glucagon
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...