Validation of the cell culture monitoring using a Raman spectroscopy calibration model developed with artificially
Risa Hara1, Wataru Kobayashi2, Hiroaki Yamanaka2
1Research and Development Department, Yokogawa Electric Corporation, Musashino, Tokyo, 180-8750, Japan. Risa.Hara@yokogawa.com.
Abstract:
The development of calibration models using Raman spectra data has long been challenged owing to the substantial time and cost required for robust data acquisition. To reduce the number of experiments involving actual incubation, a calibration model development method was investigated by measuring artificially mixed samples. In this method, calibration datasets were prepared using spectra from artificially mixed samples with adjusted concentrations based on design of experiments. The precision of these calibration models was validated using the actual cell culture sample. The results showed that when the culture conditions were unchanged, the root mean square error of prediction (RMSEP) of glucose, lactate, and antibody concentrations was 0.34, 0.33, and 0.25 g/L, respectively. Even when variables such as cell line or culture media were changed, the RMSEPs of glucose, lactate, and antibody concentrations remained within acceptable limits, demonstrating the robustness of the calibration models with artificially mixed samples. To further improve accuracy, a model training method for small datasets was also investigated. The spectral pretreatment conditions were optimized using error heat maps based on the first batch of each cell culture condition and applied these settings to the second and third batches. The RMSEPs improved for glucose, lactate, and antibody concentration, with values of 0.44, 0.19, and 0.18 g/L under constant culture conditions, 0.37, 0.12, and 0.12 g/L for different cell lines, and 0.26, 0.40, and 0.12 g/L when the culture media was changed. These results indicated the efficacy of calibration modeling with artificially mixed samples for actual incubations under various conditions.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...