Related Experiment Video
Updated: Jul 8, 2025

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
The effect of high-flow nasal oxygen flow rate on gas exchange in apnoeic patients: a randomised controlled trial
C Lyons1, J McElwain1, O Young2
1Department of Anaesthesia, Galway University Hospitals, Galway, Ireland.
Abstract:
High-flow nasal oxygen can be administered at induction of anaesthesia for the purposes of pre-oxygenation and apnoeic oxygenation. This intervention is claimed to enhance carbon dioxide elimination during apnoea, but the extent to which this occurs remains poorly quantified. The optimal nasal oxygen flow rate for gas exchange is also unknown. In this study, 114 patients received pre-oxygenation with high-flow nasal oxygen at 50 l.min-1. At the onset of apnoea, patients were allocated randomly to receive one of three nasal oxygen flow rates: 0 l.min-1; 70 l.min-1; or 120 l.min-1. After 4 minutes of apnoea, all oxygen delivery was ceased, tracheal intubation was performed, and oxygen delivery was recommenced when SpO2 was 92%. Mean (SD) PaCO2 rise during the first minute of apnoea was 1.39 (0.39) kPa, 1.41 (0.29) kPa, and 1.26 (0.38) kPa in the 0 l.min-1, 70 l.min-1 and 120 l.min-1 groups, respectively; p = 0.16. During the second, third and fourth minutes of apnoea, mean (SD) rates of rise in PaCO2 were 0.34 (0.08) kPa.min-1, 0.36 (0.06) kPa.min-1 and 0.37 (0.07) kPa.min-1 in the 0 l.min-1, 70 l.min-1 and 120 l.min-1 groups, respectively; p = 0.17. After 4 minutes of apnoea, median (IQR [range]) arterial oxygen partial pressures in the 0 l.min-1, 70 l.min-1 and 120 l.min-1 groups were 24.5 (18.6-31.4 [12.3-48.3]) kPa; 36.6 (28.1-43.8 [9.8-56.9]) kPa; and 37.6 (26.5-45.4 [11.0-56.6]) kPa, respectively; p < 0.001. Median (IQR [range]) times to desaturate to 92% after the onset of apnoea in the 0 l.min-1, 70 l.min-1 and 120 l.min-1 groups, were 412 (347-509 [190-796]) s; 533 (467-641 [192-958]) s; and 531 (462-681 [326-1007]) s, respectively; p < 0.001. In conclusion, the rate of carbon dioxide accumulation in arterial blood did not differ significantly between apnoeic patients who received high-flow nasal oxygen and those who did not.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Respiratory Volumes and Capacities I

