Quality assurance of lead aprons for radiation protection
Periyasamy Revathy1, Shanmukhappa B Kaginelli2
1Department of Radiation Oncology, MS Ramaiah Medical College, Bangalore, Karnataka 560054, India.
Abstract:
Radiation protection is essential to minimize the harmful effects of ionizing radiation. Lead equivalent apron is one of the common protective devices to reduce the occupational risk of radiation exposure. The aim of the study is to analyse the percentage attenuation of 0.5 mm lead equivalent apron. Twenty aprons were used for calculating the percentage of attenuation. The computed tomography (CT) phantom was placed on the radiography and CT table at 1 m from the X-ray tube. The readings were taken from the phantom using a detector at 1-m distance with and without lead equivalent aprons. The readings were tabulated and analysed. The mean percentage attenuation of 0.5 mm lead equivalent apron is 95.66 ± 0.61 in radiography (100 kVp), 95.64 ± 0.57 in CT (130 kVp), respectively. The percentage attenuation of lead equivalent aprons is permissible comparing with the literature.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:36Safety Precautions and Operating Procedures in an ABSL-4 Laboratory: 4. Medical Imaging Procedures
Published on: October 3, 2016
Related Concept Videos
PPE Use in Healthcare Settings I: Donning
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Personal Protective Equipment
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...