A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers
Alfredo López-Muñoz1,2, Isabel López-Castaño1, Úrsula Torres-Parejo3
1Department of Physics of Condensed Matter, Optics Area, Vision Sciences Research Group (CIVIUS), Pharmacy School, University of Seville, 41009 Seville, Spain.
Soft contact lens wear in myopic patients showed significant changes in corneal biomechanics, specifically the deflection amplitude ratio and central corneal thickness, indicating safe adaptation. Biomechanically corrected intraocular pressure remained stable.
Area of Science:
- Ophthalmology
- Biomechanical Engineering
- Corneal Physiology
Background:
- Soft contact lenses (CLs) are widely used for myopia correction.
- Understanding their impact on corneal biomechanics is crucial for patient safety.
- The Corvis ST (CST) analyser provides advanced biomechanical measurements.
Purpose of the Study:
- To evaluate biomechanical changes in the cornea after soft CL wear in healthy myopic patients.
- To assess the safety and stability of corneal stiffness with CL use.
- To analyze specific biomechanical parameters using the CST analyser.
Main Methods:
- Prospective, cross-sectional study of 22 Caucasian myopic patients (19-24 years).
- Measurements included five biomechanical parameters, central corneal thickness (CCT), and biomechanically corrected intraocular pressure (bIOP) using CST.
- Data collected pre-fitting and one month post-CL wear.
Main Results:
- Significant differences observed in deflection amplitude ratio (DA Ratio) and standard deviation of DA Ratio (SD DA Ratio) pre- and post-CL wear (p=0.002).
- Significant increase in central corneal thickness (CCT) post-CL wear (p=0.013).
- No significant differences in other biomechanical measures or bIOP pre- and post-CL wear.
Conclusions:
- Soft CL fitting is a safe optical compensation method, maintaining corneal stiffness stability.
- Corneal biomechanical indices from CST support the safety of soft CL wear.
- No significant alterations in bIOP were detected after one month of soft CL use.