Related Experiment Video
Updated: Jul 7, 2025

Finite Element Modelling of a Cellular Electric Microenvironment
Published on: May 18, 2021
Research on 18th-Century Building Structures in Terms of Static Scheme Changes
Monika Mackiewicz1, Janusz Ryszard Krentowski1, Kamil Zimiński1
1Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45E, 15-351 Bialystok, Poland.
Assessing historic 18th-century buildings requires evaluating defects that alter structural integrity. Non-destructive testing and computational analysis reveal how past repairs and material degradation change static schemes, informing necessary interventions.
Area of Science:
- Structural Engineering
- Heritage Conservation
- Building Diagnostics
Background:
- Evaluating the technical condition of historic buildings, especially those several centuries old, presents significant challenges.
- Many 18th-century structures lack original elements due to past renovations often performed with variable quality materials and methods.
- Material degradation, inadequate repairs, and loss of support in historic structures can alter load transfer paths and change the original static scheme.
Purpose of the Study:
- To provide an overview of defects that cause changes in static schemes within 18th-century historical building structures.
- To demonstrate the assessment process for a historic building exhibiting numerous defects.
- To analyze the technical condition of a specific wooden roof truss structure that has partially lost its support.
Main Methods:
- Utilized non-destructive testing (NDT) methods for technical condition assessment.
- Conducted detailed computational analyses on the wooden roof truss structure.
- Examined defects affecting the static schemes of historical building structures.
Main Results:
- Identified various defects leading to altered static schemes in the studied 18th-century building.
- The assessment process highlighted the complexity of evaluating structures with a history of poor-quality repairs.
- Computational analysis provided insights into the behavior of the compromised wooden roof truss.
Conclusions:
- The study underscores the importance of thorough technical assessments for historic buildings.
- Understanding altered static schemes is crucial for effective repair and strengthening strategies.
- NDT and computational analysis are vital tools for diagnosing and preserving aging structures.
Related Concept Videos
Indeterminate Structure
Introduction to Structures
There are three main...
Constraints and Statical Determinacy
Static Equilibrium - II
Masonry Loadbearing Walls
Reinforced Brick Masonry
To fortify brick walls...