A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Can Wrist-Worn Medical Devices Correctly Identify Ovulation?
Angela Niggli1,2, Martina Rothenbühler3, Maike Sachs1,2
1Department of Reproductive Endocrinology, University Hospital of Zürich, Frauenklinikstrasse 10, 8091 Zürich, Switzerland.
Abstract:
(1) Background: Hormonal fluctuations across the menstrual cycle lead to multiple changes in physiological parameters such as body temperature, cardiovascular function, respiratory rate and perfusion. Electronic wearables analyzing those parameters might present a convenient alternative to urinary ovulation tests for predicting the fertile window. (2) Methods: We conducted a prospective observational study including women aged 18-45 years without current hormonal therapy who used a wrist-worn medical device and urinary ovulation tests for a minimum of three cycles. We analyzed the accuracy of both the retrospective and prospective algorithms using a generalized linear mixed-effects model. The findings were compared to real-world data from bracelet users who also reported urinary ovulation tests. (3) Results: A total of 61 study participants contributing 205 cycles and 6081 real-life cycles from 3268 bracelet users were included in the analysis. The mean error in identifying ovulation with the wrist-worn medical device retrospective algorithm in the clinical study was 0.31 days (95% CI -0.13 to 0.75). The retrospective algorithm identified 75.4% of fertile days, and the prospective algorithm identified 73.8% of fertile days correctly within the pre-specified equivalence limits (±2 days). The quality of the retrospective algorithm in the clinical study could be confirmed by real-world data. (4) Conclusion: Our data indicate that wearable sensors may be used to accurately detect the periovulatory period.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.