Related Experiment Video
Updated: Jul 7, 2025

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
An axially slanted illumination back-scattering Raman scheme for direct determination of component concentration of
Haeseong Jeong1, Seoyeon Jeong1, Jaejin Kim2
1Department of Chemistry and Research Institute for Convergence of Basic Science, Hanyang University, Seoul 04763, Republic of Korea.
Abstract:
For direct and non-sampling determination of the component concentration of a sample housed in a glass container, an axially slanted illumination (ASI) back-scattering Raman scheme that reduces glass background interference has been demonstrated. The strategy was to increase the distance between the spots illuminated by the laser on the glass container and the housed sample in back-scattering measurement. For realization, the laser initially illuminated at a slant through the upper side of the vial wall (sample-unoccupied space) and reach the top of the sample. By this way, fewer number of generated glass photons could be recognized by a detector since they are farther from the focal plane (sample-illumination spot). The concentration of rosuvastatin (2.98-4.14 wt%) in rosulord samples (mixed with five other excipients) was determined using the ASI back-scattering measurement. When the angle of illumination to the vertical axis was 30° and the distance from the center of the laser spot on the glass wall to the center of spot on the sample (DG-S) was 14.9 mm, the sample peaks became more apparent and characteristic due to the reduced glass background. The accuracy of the concentration measurement was superior to that obtained through conventional back-scattering, in which the DG-S was nearly zero. The proposed scheme provides a simple optical setting to suppress the glass background and takes advantage of the sensitivity of Raman analysis through back-scattering measurement, indicating it as an attractive option for through-container analysis.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...