Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

378
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
378

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Volatile organic compound profiling for tracking clinical Pseudomonas aeruginosa isolates.

Scientific reports·2026
Same author

Transthyretin is a novel innate immune effector against Gram negative bacteria.

PLoS pathogens·2026
Same author

Analyzing the effects of benzodiazepines on the virulence and biofilm formation of Pseudomonas aeruginosa.

Scientific reports·2025
Same author

Rethinking Cryptophane-A for Methane Gas Sensing: Cross-Sensitivity to N<sub>2</sub> and CO<sub>2</sub> at Ambient Conditions.

Analytical chemistry·2025
Same author

Metabolomic profiling reveals unique markers for Pseudomonas aeruginosa LasR deficiency.

Scientific reports·2025
Same author

Corticosteroids modulate biofilm formation and virulence of <i>Pseudomonas aeruginosa</i>.

Biofilm·2025

Related Experiment Video

Updated: Jul 7, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
10:42

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

Published on: March 22, 2019

6.3K

Sub-ppm Methane Detection with Mid-Infrared Slot Waveguides.

Henock D Yallew1, Marek Vlk1, Anurup Datta1

  • 1Department of Physics and Technology, UiT The Arctic University of Norway, NO-9037 Tromsø, Norway.

ACS Photonics
|December 25, 2023
PubMed
Summary
This summary is machine-generated.

Researchers developed a highly sensitive nanophotonic waveguide for methane detection, significantly improving on-chip spectroscopy for climate and industrial applications. This breakthrough offers a 0.3 ppm limit of detection, advancing miniaturized sensor technology.

More Related Videos

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
05:00

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer

Published on: July 26, 2024

450
Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
08:18

Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions

Published on: June 12, 2016

16.8K

Related Experiment Videos

Last Updated: Jul 7, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
10:42

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing

Published on: March 22, 2019

6.3K
Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
05:00

Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer

Published on: July 26, 2024

450
Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
08:18

Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions

Published on: June 12, 2016

16.8K

Area of Science:

  • Photonics
  • Spectroscopy
  • Sensor Technology

Background:

  • Chip-scale laser spectroscopic sensors are crucial for climate research and industry.
  • Current limitations include lossy waveguides, weak light-analyte interaction, and etalon effects.
  • These challenges hinder the sensitivity of miniaturized devices.

Purpose of the Study:

  • To develop a highly sensitive nanophotonic waveguide for methane detection.
  • To overcome limitations in on-chip spectroscopy sensitivity.
  • To investigate the impact of humidity on mid-infrared waveguides.

Main Methods:

  • Designed a silicon slot waveguide for enhanced light-analyte interaction at 3270.4 nm.
  • Utilized double-tip fork couplers to suppress etalon fringes.
  • Studied the effect of adsorbed humidity on mid-infrared waveguide performance.

Main Results:

  • Achieved a limit of detection of 0.3 ppm for methane.
  • Demonstrated a sensitivity over 2 orders of magnitude lower than state-of-the-art on-chip spectroscopy.
  • Identified and discussed the overlooked effect of humidity on waveguide performance.

Conclusions:

  • The developed nanophotonic waveguide significantly advances on-chip methane detection sensitivity.
  • The design overcomes key limitations in current chip-scale spectroscopic sensors.
  • Further research should consider environmental factors like humidity for mid-infrared applications.