Related Experiment Video
Updated: Jul 7, 2025

Optimization of the Epimedii Folium Mutton-Oil Processing Technology and Testing Its Effect on Zebrafish Embryonic Development
Published on: March 17, 2023
Optimization and validation of high-performance liquid chromatography using modified QuEChERS to determine
Hiwa Muhammad Husein Hiwa1,2, Khulod Ibraheem Hassan Khulod3
1Sulaimaniyah New Slaughterhouse, Sulaimaniyah Directorate of Veterinary Medicine, Sulaimaniyah, Kurdistan Region, Iraq.
Abstract:
The aim of this study was to rapidly determine the presence of anthelmintic drugs in sheep meat using the optimized high-performance liquid chromatography-ultraviolet (HPLC-UV) method with modified QuEChERS (quick, easy, cheap, effective, rugged, safe) technology. Fifty fresh sheep meat samples from different slaughterhouses were collected. A double extraction procedure (QuEChERS/HPLC-UV technology) was used to extract the target analytes. A multilevel calibration curve from 1 to 1000 g/kg was used to establish instrument linearity for rafoxanide, albendazole, and closantel, whereas 0.1-100 μg/kg was used for ivermectin, levamisole, and oxyclozanide to find the lowest concentration, maximum residue limit (MRL), and occupied range for targeted analytes. The concentration levels were used to investigate the linearity, whereas several certified reference materials were applied to determine accuracy. The process was linear for all combinations, from the limit of quantification (LOQ) to the maximum concentration. The LOQ was established at 0.5 μg/kg for ivermectin, levamisole, and oxyclozanide and 10 μg/kg for rafoxanide, albendazole, and closantel. Recovery values were 70%-120%, and repeatability/reproducibility stated in relative standard deviation was obtained at less than 20%. QuEChERS method revealed that most meat samples contained anthelmintic drug residues, of which the majority exceeded the MRLs. Thus, the drugs should be used correctly in animals to avoid residues in food for human consumption.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...