Development of hydrogel-based standards and phantoms for non-linear imaging at depth

Fizza Haseeb1, Konstantinos N Bourdakos2, Ewan Forsyth1

  • 1University of Edinburgh, School of Chemistry, Edinburgh, United Kingdom.

PubMed
Abstract

Related Concept Videos

Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Deconvolution01:20

Deconvolution

Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Uniform Depth Channel Flow01:27

Uniform Depth Channel Flow

Uniform depth channel flow keeps fluid depth consistent along channels such as irrigation canals. In natural channels, such as rivers, approximate uniform flow is often assumed. This condition occurs when the channel’s bottom slope matches the energy slope, balancing potential energy lost from gravity with head loss due to shear stress. This balance prevents depth changes along the channel length, resulting in a steady, uniform flow.Uniform flow in open channels with a constant cross-section...