Effect of Arterialization on Venous Blood Glucose Concentrations and Implications for Observed Continuous Glucose
Stefan Pleus1, Manuela Link1, Rolf Hinzmann2
1Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Abstract:
Background: Heating of the arm and/or hand ("arterialization") is sometimes used in continuous glucose monitoring (CGM) performance studies with the reported aim of reducing differences between venous and capillary glucose concentrations. In this study, the effect of heating on venous glucose concentrations and CGM accuracy was investigated. Methods: A heating pad set to 50°C (122°F) was used with 20 participants to heat either the dominant or nondominant arm and hand. Venous and capillary samples were obtained every 15 min on both arms throughout each of three 6-h glucose challenges. CGM sensors were worn on each upper arm for each of the three visits. Results: Heating of the arm led to a median increase in venous glucose concentrations of +1.4%. No similar effect on capillary concentrations was observed. As a result, the median capillary to venous difference decreased from +5.9% in the nonheated arm to +4.2% in the heated arm. CGM accuracy observed in this study was affected by the selection of heated venous, nonheated venous, or capillary glucose concentrations as comparator data. The heating effect was more pronounced with rapidly decreasing glucose concentrations. Temperatures on the skin did not exceed 40°C (104°F). No adverse events or protocol deviations were associated with the use of the heating pad. Conclusions: Heating of the arm led to a small increase in venous glucose concentrations, but venous concentrations did not reach the level of capillary glucose concentrations. CGM accuracy observed in this study varied depending on the selected comparator data. This study was registered at the German Clinical Trials Register (DRKS00031197).
Related Concept Videos
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement


