Sustainable Purchasing Practices: A Comparison of Single-use and Reusable Pulse Oximeters in the Emergency Department
Juliana Duffy1, Jonathan E Slutzman2,3, Cassandra L Thiel4
1University of Toronto, Temerty Faculty of Medicine, Division of Emergency Medicine, Toronto, Ontario, Canada.
Background:
Delivering healthcare requires significant resources and creates waste that pollutes the environment, contributes to the climate crisis, and harms human health. Prior studies have generally shown durable, reusable medical devices to be environmentally superior to disposables, but this has not been investigated for pulse oximetry probes.
Objective:
Our goal was to compare the daily carbon footprint of single-use and reusable pulse oximeters in the emergency department (ED).
Methods:
Using a Life Cycle Assessment (LCA), we analyzed greenhouse gas (GHG) emissions from pulse oximeter use in an urban, tertiary care ED, that sees approximately 150 patients per day. Low (387 uses), moderate (474 uses), and high use (561 uses), as well as cleaning scenarios, were modelled for the reusable oximeters and compared to the daily use of single-use oximeters (150 uses). We calculated GHG emissions, measured in kilograms of carbon dioxide equivalents (kgCO2e), across all life cycle stages using life-cycle assessment software and the ecoinvent database. We also carried out an uncertainty analysis using Monte Carlo methodology and calculated the break-even point for reusable oximeters.
Results:
Per day of use, reusable oximeters produced fewer greenhouse gases in low-, moderate-, and high-use scenarios compared to disposable oximeters: 3.9 kgCO2e, 4.9 kgCO2e, 5.7 kgCO2e vs 23.4 kgCO2e, respectively). An uncertainty analysis showed there was no overlap in emissions, and a sensitivity analysis found reusable oximeters only need to be used 2.3 times before they match the emissions created by a single disposable oximeter. Use phases associated with the greatest emissions varied between oximeters, with the cleaning phase of reusables responsible for the majority of its GHG emissions (99%) compared to the production phases of the single-use oximeter (74%).
Conclusion:
Reusable pulse oximeters generated fewer greenhouse gas emissions per day of use than their disposable counterparts. Given that the pulse oximeter is an ubiquitous piece of medical equipment used in emergency care globally, carbon emissions could be significantly reduced if EDs used reusable rather than single-use, disposable oximeters.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: