Introduction:
In this study we aimed to investigate the prognostic accuracy for predicting in-hospital mortality using respiratory Sequential Organ Failure Assessment (SOFA) scores by the conventional method of missing-value imputation with normal partial pressure of oxygen (PaO2)- and oxygen saturation (SpO2)-based estimation methods.
Methods:
This was a single-center, retrospective cohort study of patients with suspected infection in the emergency department. The primary outcome was in-hospital mortality. We compared the area under the receiver operating characteristics curve (AUROC) and calibration results of the conventional method (normal value imputation for missing PaO2) and six SpO2-based methods: using methods A, B, PaO2 is estimated by dividing SpO2 by a scale; with methods C and D, PaO2 was estimated by a mathematical model from a previous study; with methods E, F, respiratory SOFA scores was estimated by SpO2 thresholds and respiratory support use; with methods A, C, E are SpO2-based estimation for all PaO2 values, while methods B, D, F use such estimation only for missing PaO2 values.
Results:
Among the 15,119 patients included in the study, the in-hospital mortality rate was 4.9%. The missing PaO2was 56.0%. The calibration plots were similar among all methods. Each method yielded AUROCs that ranged from 0.735-0.772. The AUROC for the conventional method was 0.755 (95% confidence interval [CI] 0.736-0.773). The AUROC for method C (0.772; 95% CI 0.754-0.790) was higher than that of the conventional method, which was an SpO2-based estimation for all PaO2 values. The AUROC for total SOFA score from method E (0.815; 95% CI 0.800-0.831) was higher than that from the conventional method (0.806; 95% CI 0.790-0.822), in which respiratory SOFA was calculated by the predefined SpO2 cut-offs and oxygen support.
Conclusion:
In non-ICU settings, respiratory SOFA scores estimated by SpO2 might have acceptable prognostic accuracy for predicting in-hospital mortality. Our results suggest that SpO2-based respiratory SOFA score calculation might be an alternative for evaluating respiratory organ failure in the ED and clinical research settings.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...