Related Experiment Video
Updated: Jun 21, 2026

Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010
Surface Oxygen Deficiency Enabled Spontaneous Antiprotein Fouling in WO3 Nanosheets for Biosensing in Biological
Guozhen He1,2,3, Tao Dong1,2, Zhaochu Yang1,3
1Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Academician and Expert Workstation, Chongqing Technology and Business University, Nan'an District, Chongqing 400067, China.
Abstract:
Biofouling deteriorates the performance of sensors operated in biofluids. Protein adsorption is believed to be the first step of biofouling, which also reduces biocompatibility by further inducing cell adhesion, platelet activation, and even inflammation. Current studies of antifouling coatings are focused on polymers and hydrogels, which have succeeded in remaining resistant to protein adsorption, but their application on sensor electrodes is limited due to low conductivity and biocompatibility. Here, we report a spontaneous antibiofouling strategy for sensor electrodes by controlling oxygen vacancies in WO3 nanosheets. Irreversible adsorption of proteins was reduced by 76% in unprocessed human plasma when electrodes were coated with WO3 rich in surface oxygen vacancy. These electrodes maintained 91% of the initial current density after 1 month of incubation in human plasma.