Ultra-stable control near the EP in non-Hermitian systems and high-precision angular rate sensing applications
Abstract:
In non-Hermitian systems, enhancing sensitivity under exceptional point (EP) conditions offers an ideal solution for reconciling the trade-off between sensitivity and size constraints in sensing applications. However, practical application is limited by undesired sensitivity to external fluctuations, noise, and errors in signal amplification synchronization. This paper presents a precisely controlled EP tracking and detection system (EPTDS) that achieves long-term rapid tracking and locking near the EP by constructing a second-order non-Hermitian optical sensing unit, employing an optical power adaptive control method, and utilizing a combinatorial demodulation-based dual-loop cascaded control (CDCC) technique to selectively suppress traditional noise at different frequencies. The system locking time is 10 ms, and in room temperature conditions, the output frequency error over 1 hour is reduced by more than 30 times compared to before locking. To assess its sensing capabilities, the EPTDS undergoes testing in a rotational experiment based on the Sagnac effect, with the output bias instability based on Allan deviation measured at 0.036 °/h. This is the best result for EP-enhanced angular rate sensing that we are aware of that has been reported. The EPTDS method can be extended to various sensing fields, providing a new path for transitioning non-Hermitian sensing from the laboratory to practical applications.
Related Concept Videos
Control Systems
At the heart...
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...