Evaluation of the Curing of Adhesive Systems by Rheological and Thermal Testing
Published on: July 3, 2020
Pulpal Temperature Variances During Step-by-step Adhesive Restorative Procedure Using Three Different High-irradiance
R K Nakagawa1, H H Araújo de Oliveira2, L G Abreu3
1Rodrigo Keigo Nakagawa, DDS, MSc, PhD, postdoctoral researcher, Department of Restorative Dentistry, Federal University of Minas Gerais, Bel o Horizonte, Brazil.
Abstract:
The rise in temperature in pulp tissues is related not only to heat transfer by high-irradiance light-curing units (LCUs), but also to restorative procedures. This research aimed to compare the rise in pulp temperature (PT) induced by three LCUs at each restorative step while considering the influence of resin composite shade and thickness. To accomplish this, the investigators used a proposed experimental model replicating pulp fluid circulation with a controlled, simulated intraoral temperature in bovine incisors. The recorded external and internal PT ranged from 36.7°C to 37.1°C and 32.7°C to 33.0°C, respectively. A significant decrease of internal temperature was recorded during class V preparation, followed by a progressive and representative rise of temperature in the subsequent restorative steps. The temperature was significantly higher during light curing of the adhesive system using Valo compared to light curing using Elipar and Radii Cal. However, none of the analyzed devices produced a temperature that exceeded the pulp tolerance limit (a temperature increase over 5.5°C). The paired test showed no significant difference in pulp temperature associated with the thickness of the increment of resin composite. However, shade was found to have more influence on the amount of energy absorbed by pulp tissue-A1 samples showed significantly higher temperature variation compared to samples using the A4 shade of resin composite. To conclude, the microcirculation and the performance of procedures under constant air-water flux dissipate the heat absorbed by the pulp. Additionally, the data suggest that all three LCUs analyzed can be safely used in clinical procedures, and that the resin composite shade may influence the amount of irradiance delivered to the tooth surface and represents a significant factor in pulp temperature variance.
Related Concept Videos
Decreased Body Temperature
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...