Methylation Specific Multiplex Droplet PCR using Polymer Droplet Generator Device for Hematological Diagnostics
Published on: June 29, 2020
A high-throughput droplet digital PCR system aiming eight DNA methylation targets for age prediction
Yuxiang Zhou1, Yanyun Wang2, Mengyuan Song3
1Department of Forensic Genetics, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu 610041, China.
Abstract:
The droplet digital Polymerase Chain Reaction (ddPCR) has garnered recognition for its distinctive attribute of absolute quantification. And it has found practical utility in age prediction through DNA methylation profiles. However, a prevalent limitation in current ddPCR methodologies is the restricted capacity to detect only two targets concurrently in most instruments, leading to high costs, sample wastage, and labor-intensive procedures. To address the limitations, a novel high-throughput ddPCR system allowing for the simultaneous detection of eight targets was developed. Through the implementation of a new 8-plex ddPCR assay, coupled with comprehensive linear regression analyses involving primers and probes ratios, diverse inputs of single CpG sites with distinct primers and probes, and varying plex assay configurations, stable DNA methylation values for four CpGs and stable measurement precisions for distinct multiplex systems were consistently observed. These findings pave the way for advancing the field of chemistry science by enabling more efficient and cost-effective methods. Furthermore, the comparative validation of ddPCR and SNaPshot demonstrated a remarkable concordance in results, and the system also displayed well in the field of various aspects, including species specificity, DNA input, and aged samples. In this study, the recommended input of bisulfite-converted DNA was determined to be 10-50 ng due to the double-positive droplets. Notably, the Pearson correlation coefficient squared values of four CpGs were 0.4878 (ASPA), 0.4832 (IGSF1), 0.6881 (COL1A1), and 0.6475 (MEIS1-AS3). And the testing set exhibited a mean absolute error of 4.5923 years, indicating the robustness and accuracy of the age-predictive model.
More Related Videos
08:23Single Droplet Digital Polymerase Chain Reaction for Comprehensive and Simultaneous Detection of Mutations in Hotspot Regions
Published on: September 25, 2018
09:15Measuring Single-Cell Mitochondrial DNA Copy Number and Heteroplasmy Using Digital Droplet Polymerase Chain Reaction
Published on: July 12, 2022