Related Experiment Video
Updated: Jul 6, 2025

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
An in-fiber sensor for simultaneous measurement of cholesterol concentration and temperature based on SPR and MMI
Wanlu Zheng1, Bo Han2, Ya-Nan Zhang3
1College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China.
Abstract:
In this paper, we design an in-fiber two-parameter sensor with multimode fiber (MMF)-Au film coated hollow fiber (HCF)-MMF structure, which can simultaneously excite Surface Plasmon Resonance (SPR) effect and Multimode Interference (MMI) effect. A composite material of Au nanoparticles/β-cyclodextrin (AuNPs/β-CD) is deposited on the surface of the Au film coated HCF to realize highly-sensitive measurement of cholesterol concentration. Here, the AuNPs can not only enhance the measurement sensitivity of the SPR sensor, but also increase the numbers of combination sites of β-CD and cholesterol. Then, to solve the cross-sensitivity problem between temperature and cholesterol, the glycerin is selected as a temperature-sensitive material to fill into the inner channel of the HCF, making the MMI sensor sensitive to temperature, and finally realizing the simultaneous measurement of cholesterol concentration and temperature. The experimental results demonstrate that the wavelength shift of the SPR and the MMI are 12.7 nm and 7.9 nm, respectively, when the cholesterol concentration changes from 0 to 500 nM. The temperature sensitivity of the SPR and the MMI are -0.9 nm/°C and 2.64 nm/°C, respectively, in the temperature range of 30°C-46 °C. In addition, the sensor shows good recognition ability of cholesterol molecules in serum environment, with good stability, selectivity and repeatability, and has broad application prospects in the biomedical field.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

