Evaluating the impact of external forces on peripheral intravenous catheter movement using ultrasound: A randomized
Amit Bahl1, Vance Clement2, Emily DiLoreto1
1Department of Emergency Medicine, Corewell Health William Beaumont University Hospital, Royal Oak, MI, USA.
Background:
A major contributor to peripheral intravenous catheter (PIVC) failure may be related to PIVC movement within the vein which is associated with vein wall damage. The magnitude of PIVC movement against the vein wall has not previously been quantified. This study aimed to examine PIVC movement within the vein when minor forces were applied to the PIVC.
Methods:
This was a prospective, pilot trial including healthy volunteers in an outpatient research laboratory. The primary objective was to examine the in movement (millimeters) of the PIVC using ultrasound with external pull forces (4, 5, and 6 lbs; 1.8, 2.3, and 2.7 kg, respectively) applied to the PIVC in random order.
Results:
Participants (N = 11) were aged 40.36 ± 16.10 years with 54.55% being Male. Mean ± SD PIVC movement for 4, 5, and 6 lbs of force was 4.65 ± 1.88, 3.88 ± 2.28, and 5.25 ± 2.06 mm, respectively. There was substantial PIVC movement when a force was applied to the PIVC, but no statistically significant difference between 4, 5, and 6 lb forces (p > 0.05).
Conclusion:
When external pull forces were applied to the PIVC, substantial PIVC movement within the vein occurred in a healthy population. Strategies that reduce PIVC movement and/or remove or limit external pull forces from the PIVC are needed. Future studies on hospitalized patients are warranted to quantify vein wall injury and PIVC failure due to PIVC movement from various pull forces.
More Related Videos
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
10:09Drug Treatment by Central Venous Catheter in a Mouse Model of Angiotensin II Induced Abdominal Aortic Aneurysm and Monitoring by 3D Ultrasound
Published on: August 4, 2022
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: