Mark E Wilson1, Wes W C Quigley2, Angela C Davis3
1Boeing Research & Technology, 499 Boeing Blvd., Mail Code JN-71, Huntsville, AL 35824.
Aims:
To test the efficacy of 222 nm Far UV-C for surface disinfection of SARS-CoV-2 on inanimate surfaces from airplane cabins.
Methods And Results:
Two far ultraviolet (UV-C) irradiation light systems were evaluated for disinfection of SARS-CoV-2. Materials used for carriers (test surfaces) included polished stainless steel and used airplane materials including seatbelt latches, window dust covers, sidewall laminates, and tray tables.
Conclusions:
While demonstrating reasonable efficacy under some experimental conditions, the data indicated that 222 nm Far UV-C disinfection alone does not reliably provide a 3 log10 or 99.9% reduction of SARS-CoV-2 on inanimate surfaces from an airplane cabin. An Ushio (Cypress, CA) 1.7" x 2.3" Care222® 12W 222nm BI lamp module tested in triplicate at a low (⁓ 1.5 mJ cm-2), medium (⁓ 3.0 mJ cm-2), and high (⁓ 6 to 9 mJ cm-2) fluence did not provide a ≥ 3 log10 or 99.9% reduction of SARS-CoV-2. The reduction of SARS-CoV-2 was greatest on stainless steel. The result was a log10 reduction of 2.83, 1.33, 2.58, and 2.21 logs for virus samples containing saline, saline with 2.5 mg BSA, saline with 0.25 mg BSA, and artificial saliva respectively at a dosage of 5 to 9 mJ cm-2. The log10 reduction of SARS-CoV-2 in saline with 2.5 mg bovine serum albumin was lowest with 1.33 for stainless steel, 0.93 for belt latch, and 0.61 for tray table at a dosage of 5 to 6 mJ cm-2.The second UV lighting system tested was a prototype mobile wand with a built-in short-pass filtered krypton-chloride cylindrical lamp. One pass of the wand over a tray holding carriers inoculated with SARS-CoV-2 in artificial saliva at a rate of approximately 1 foot (1') per second (sec) exposed the carriers to 7.3 mJ cm-2. The log10 reductions determined for the single pass were 2.97, 3.75, 1.78, 1.91, and 1.28 logs for stainless steel, belt latch, dust cover, sidewall, and tray table respectively. Two passes of the wand generated 17.2 mJ cm-2 and resulted in log10 reductions of 4.04, 3.74, 4.24, 3.68, and 1.66 logs for stainless steel, belt latch, dust cover, sidewall, and tray table respectively. The combination of higher fluence from multiple passes of the wand, the close proximity (10 cm wand to the carrier), the exposure to elevated temperatures up to 35°C, and ozone from the bulb being blown directly onto the carriers contributed to effective viral inactivation on all surfaces except the airplane tray table. The impact of temperature and ozone on viral inactivation should be determined for future testing of the 222 nm UV-C wand.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Mutations
Chromosomal Alterations Are Large-Scale Mutations
While point mutations are changes in a single nucleotide in...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...