Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Bismuth Shielding in Head Computed Tomography-Still Necessary?
Jana Di Rosso1, Andreas Krasser2, Sebastian Tschauner1
1Division of Paediatric Radiology, Department of Radiology, Medical University of Graz, 8036 Graz, Austria.
Abstract:
Introduction: Cranial CT scans are associated with radiation exposure to the eye lens, which is a particularly radiosensitive organ. Children are more vulnerable to radiation than adults. Therefore, it is essential to use the available dose reduction techniques to minimize radiation exposure. According to the European Consensus on patient contact shielding by the IRCP from 2021, shielding is not recommended in most body areas anymore. This study aims to evaluate whether bismuth shielding as well as its combination with other dose-saving technologies could still be useful. Methods: Cranial CT scans of a pediatric anthropomorphic phantom were performed on two up-to-date MDCT scanners. Eye lens dose measurements were performed using thermoluminescent dosimeters. Furthermore, the impact of BS and of the additional placement of standoff foam between the patient and BS on image quality was also assessed. Results: Bismuth shielding showed a significant lens dose reduction in both CT scanners (GE: 41.50 ± 4.04%, p < 0.001; Siemens: 29.75 ± 6.55%, p = 0.00). When combined with AEC, the dose was lowered even more (GE: 60.75 ± 3.30%, p < 0.001; Siemens: 41.25 ± 8.02%, p = 0.00). The highest eye dose reduction was achieved using BS + AEC + OBTCM (GE: 71.25 ± 2.98%, p < 0.001; Siemens: 58.75 ± 5.85%, p < 0.001). BS caused increased image noise in the orbital region, which could be mitigated by foam placement. Eye shielding had no effect on the image noise in the cranium. Conclusions: The use of BS in cranial CT can lead to a significant dose reduction, which can be further enhanced by its combination with other modern dose reduction methods. BS causes increase in image noise in the orbital region but not in the cranium. The additional use of standoff foam reduces image noise in the orbital region.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
X-ray Imaging