A Bibliometric and Comprehensive Review on Condition Monitoring of Metal Oxide Surge Arresters
Tiago Goncalves Zacarias1,2, Wilson Cesar Sant'Ana1
1Office of Research and Graduate Studies (PRPPG), Federal University of Itajuba, Itajuba 37500-903, MG, Brazil.
Abstract:
This paper presents a literature review on the subject of Condition-Based Maintenance of surge arresters. Both a bibliometric analysis and traditional comprehensive research are presented. The bibliometric analysis is useful for obtaining insights about the literature. It quantitatively highlights relationships between journals, authors and keywords (related to the monitoring methods) and reveals future trends for research based on the timeline of the keywords. The traditional comprehensive literature review is also presented. It summarizes the methods, their advantages and disadvantages and also points to some known measurement issues of the methods. Both online (leakage current, harmonic components, temperature, partial discharges, power loss and the counting of discharges) and offline (reference voltage, residual voltage, insulation resistance, polarization/depolarization, return voltage, microscopy, spectrometry, X-ray, RUS and the recent application of FRA) methods have been qualitatively analyzed.
Related Concept Videos
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Insulation Coordination
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Parallel RLC Circuits
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...