Related Experiment Video
Updated: Jul 5, 2025

Three-Dimensional Imaging of Aortic Tissues in Atherosclerosis
Published on: October 25, 2024
An Image Histogram Equalization Acceleration Method for Field-Programmable Gate Arrays Based on a Two-Dimensional
Yan Wang1, Peirui Liu1, Dalin Li1,2
1Key Laboratory of Symbol Computation and Knowledge Engineering of Ministry of Education, College of Computer Science and Technology, Jilin University, Changchun 130012, China.
Abstract:
New artificial intelligence scenarios, such as high-precision online industrial detection, unmanned driving, etc., are constantly emerging and have resulted in an increasing demand for real-time image processing with high frame rates and low power consumption. Histogram equalization (HE) is a very effective and commonly used image preprocessing algorithm designed to improve the quality of image processing results. However, most existing HE acceleration methods, whether run on general-purpose CPUs or dedicated embedded systems, require further improvement in their frame rate to meet the needs of more complex scenarios. In this paper, we propose an HE acceleration method for FPGAs based on a two-dimensional configurable pipeline architecture. We first optimize the parallelizability of HE with a fully configurable two-dimensional pipeline architecture according to the principle of adapting the algorithm to the hardware, where one dimension can compute the cumulative histogram in parallel and the other dimension can process multiple inputs simultaneously. This optimization also helps in the construction of a simple architecture that achieves a higher frequency when implementing HE on FPGAs, which consist of configurable input units, calculation units, and output units. Finally, we optimize the pipeline and critical path of the calculation units. In the experiments, we deploy the optimized HE on a VCU118 test board and achieve a maximum frequency of 891 MHz (which is up to 22.6 times more acceleration than CPU implementations), as well as a frame rate of 1899 frames per second for 1080p images.
More Related Videos
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
08:53Visualizing Cellular Gibberellin Levels Using the nlsGPS1 Förster Resonance Energy Transfer (FRET) Biosensor
Published on: January 12, 2019
Related Concept Videos
Upsampling
Reconstruction of Signal using Interpolation