Intraorbital pressure-volume characteristics in a piglet model: In vivo pilot study
Yasin Hamarat1, Laimonas Bartusis1, Vilma Putnynaite1
1Health Telematics Science Institute, Kaunas University of Technology, Kaunas, Lithuania.
Abstract:
Intracranial pressure measurement is frequently used for diagnosis in neurocritical care but cannot always accurately predict neurological deterioration. Intracranial compliance plays a significant role in maintaining cerebral blood flow, cerebral perfusion pressure, and intracranial pressure. This study's objective was to investigate the feasibility of transferring external pressure into the eye orbit in a large-animal model while maintaining a clinically acceptable pressure gradient between intraorbital and external pressures. The experimental system comprised a specifically designed pressure applicator that can be placed and tightly fastened onto the eye. A pressure chamber made from thin, elastic, non-allergenic film was attached to the lower part of the applicator and placed in contact with the eyelid and surrounding tissues of piglets' eyeballs. External pressure was increased from 0 to 20 mmHg with steps of 1 mmHg, from 20 to 30 mmHg with steps of 2 mmHg, and from 30 to 50 mmHg with steps of 5 mmHg. An invasive pressure sensor was used to measure intraorbital pressure directly. An equation was derived from measured intraorbital and external pressures (intraorbital pressure = 0.82 × external pressure + 3.12) and demonstrated that external pressure can be linearly transferred to orbit tissues with a bias (systematic error) of 3.12 mmHg. This is close to the initial intraorbital pressure within the range of pressures tested. We determined the relationship between intraorbital compliance and externally applied pressure. Our findings indicate that intraorbital compliance can be controlled across a wide range of 1.55 to 0.15 ml/mmHg. We observed that external pressure transfer into the orbit can be achieved while maintaining a clinically acceptable pressure gradient between intraorbital and external pressures.
More Related Videos
08:55Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
06:09Author Spotlight: Exploring Venous Waveforms in Porcine Models to Tackle Volume Overload in Medicine
Published on: January 12, 2024
Related Concept Videos
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes.
Thin-Walled Hollow Shafts
Concept of Pressure at a Point
In a fluid at rest, pressure acts equally in...
Typical Model Studies