Related Experiment Video
Updated: Jul 5, 2025

Diagnostic Ultrasound Imaging of Mouse Diaphragm Function
Published on: April 21, 2014
Non-invasive diagnosis of diaphragmatic paralysis in botulism using ultrasound
Issac Cheong1, Mariano Iván Imbelloni2, Raúl Alejandro Gómez3
1Department of Critical Care Medicine, Sanatorio de Los Arcos, Buenos Aires, Argentina; Argentinian Critical Care Ultrasonography Association (ASARUC), Argentina.
Abstract:
This case study explores foodborne botulism, a severe illness caused by botulinum neurotoxin-contaminated food. It leads to bilateral descending paralysis, involving the diaphragm. We highlight diaphragmatic ultrasound as a non-invasive diagnostic tool. A 50-year-old obese male developed diplopia and weakness after consuming contaminated food, rapidly progressing to severe symptoms. Mechanical ventilation became necessary due to respiratory failure. Diaphragmatic ultrasound confirmed bilateral diaphragm paralysis despite early antitoxin treatment. The patient experienced complications, requiring tracheostomy and rehabilitation. After five months, he fully recovered diaphragmatic function. This study underscores botulism's life-threatening nature and the vital role of supportive care. Diaphragmatic ultrasound is a safe and effective method for assessing diaphragmatic function in such cases, obviating ionizing radiation exposure. We recommend its routine use for evaluating botulism-induced paralysis.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...