Related Experiment Video
Updated: Jul 5, 2025

Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System
Published on: May 1, 2019
Using Analytical Quality by Design to improve analytical method development in vaccines quality control: Application
Isabelle Moineau1, Véronique Chambon2, Céline Perret2
1AKTEHOM, Berges du Rhône, 64 avenue Leclerc, 69007 Lyon, France.
Abstract:
Analytical quality by design (AQbD) is an enhanced approach for the development of analytical methods. AQbD has received much industrial interest, being the subject of several recently published draft guidelines. This article demonstrates the application of AQbD to determine the quantity of non-adsorbed polysaccharide polyribosyl ribitol phosphate (PRP) and percentage of depolymerized PRP in a commercial hexavalent liquid vaccine, and establishment of an analytical control strategy (ACS). The quantification method developed is high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection, preceded by ultracentrifugation (sample preparation) for separation of the depolymerized polysaccharide from the native adsorbed polysaccharide. The first step was to develop the analytical target profile (ATP) which defines the purpose of the analytical measurement as well as the development scope. As a second step, risk assessment tools were used for identification and ranking of the critical method variables (CMVs) which have a potential impact on method performance if not controlled. Based on a multivariate Design of Experiments (DoE) approach, a proposed method operational design region (MODR) was determined for seven CMVs. Finally, the ACS was established from the understanding of the analytical method and the robustness study. This article focuses on robust and operational ranges of critical parameters linked to the ultracentrifugation and chromatographic steps for depolymerized polysaccharide content control. The design space proposed for CMVs corresponds to the ranges that ensure a product that complies with the previously established precision criteria (±2% equivalent to ± 10 % around the product criterion, which is 20 % for depolymerized polysaccharide control limit). The following design space was established from the DoE statistical modeling for ultracentrifugation critical parameters: [483,000-520,000] g for speed, [11-19]°C for temperature, [29-34] minutes for duration, and from extemporaneous to 8 min for holding time before supernatant recuperation after the ultracentrifugation. For chromatographic critical parameters, the MODR is [2-6] psi for mobile phase helium pressure, [0-7] days for mobile phase storage time, and [0-3] days for samples storage time in the autosampler at 5 °C. Methods optimized using the AQbD approach provide strong justifications during regulatory filing for the selection of analytical CMVs, and for the ACS to be applied during the lifecycle management of the method.
Related Concept Videos
Ion-Exchange Chromatography
Data Validation
Key parameters for method validation include:
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
Affinity Chromatography

