Comparison of decision tree and naïve Bayes algorithms in detecting trace residue of gasoline based on gas
Md Gezani Bin Md Ghazi1,2, Loong Chuen Lee1,3, Aznor S Samsudin4
1Forensic Science Program, CODTIS, Faculty of Health Science, Universiti Kebangsaan Malaysia, Selangor, Malaysia.
Abstract:
Fire debris analysis aims to detect and identify any ignitable liquid residues in burnt residues collected at a fire scene. Typically, the burnt residues are analysed using gas chromatography-mass spectrometry (GC-MS) and are manually interpreted. The interpretation process can be laborious due to the complexity and high dimensionality of the GC-MS data. Therefore, this study aims to compare the potential of classification and regression tree (CART) and naïve Bayes (NB) algorithms in analysing the pixel-level GC-MS data of fire debris. The data comprise 14 positive (i.e. fire debris with traces of gasoline) and 24 negative (i.e. fire debris without traces of gasoline) samples. The differences between the positive and negative samples were first inspected based on the mean chromatograms and scores plots of the principal component analysis technique. Then, CART and NB algorithms were independently applied to the GC-MS data. Stratified random resampling was applied to prepare three sets of 200 pairs of training and testing samples (i.e. split ratio of 7:3, 8:2, and 9:1) for estimating the prediction accuracies. Although both the positive and negative samples were hardly differentiated based on the mean chromatograms and scores plots of principal component analysis, the respective NB and CART predictive models produced satisfactory performances with the normalized GC-MS data, i.e. majority achieved prediction accuracy >70%. NB consistently outperformed CART based on the prediction accuracies of testing samples and the corresponding risk of overfitting except when evaluated using only 10% of samples. The accuracy of CART was found to be inversely proportional to the number of testing samples; meanwhile, NB demonstrated rather consistent performances across the three split ratios. In conclusion, NB seems to be much better than CART based on the robustness against the number of testing samples and the consistent lower risk of overfitting.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...